EGSE · Test bench interface · Mission control gateway

Every bus of your bench, one box.

Stellar Bench connects your equipment under test through CAN, RS-422, RS-485, Ethernet, SpaceWire and discrete I/O, and brings every link to Stellar Control over one network cable. It runs the Stellar Control gateways natively: plug it in, and your bench is part of the mission control system.

bench-1 · integration hall B 5 links bound
Front panel of Stellar Bench: CAN, RS-422, RS-485, SpaceWire, Ethernet and GPIO connectors STELLAR BENCH CAN RS-422 RS-485 SPW ETH GPIO
10:42:07.114 CAN 0x18FF2101 · 8 B tcu-1 · direct
10:42:07.131 RS-422 payload frame · 64 B payload-em · data
10:42:07.402 ETH VOLT 28.00 psu-lab-2 · scpi
10:42:08.010 SPW packet · 1024 B camera-em · science
10:42:09.500 GPIO SEP_SW low → high separation simulated
Links bound 5 / 5
Uplink 12.4 kbit/s
Downlink 1.86 Mbit/s
Who it is for

For the benches where space hardware is tested

AIT and integration halls

Wire the flatsat once. Every bus becomes reachable from procedures, the command line and the web console.

Subsystem manufacturers

Test your unit on its own flight interfaces, and ship it with its test procedures and the same bench configuration to your customer.

Test labs

Replace PC-and-adapter setups with one identified, managed unit per bench.

NewSpace integrators

Take the same box from the lab to the clean room to the launch site; only the topology changes.

Interfaces

All the flight interfaces, one box

CAN

Platform buses

Propulsion and power units, platform buses, CSP networks.

RS-422

Point-to-point links

Payloads, instruments and avionics links.

RS-485

Multi-drop buses

Several units on one pair, as they are wired on board.

Ethernet

Equipment network

Instruments, power supplies and Ethernet-based equipment, SCPI included.

SpaceWire

High-rate links

Instruments and on-board computers that speak SpaceWire.

GPIO

Discrete signals

Enables, separation switches, status lines and triggers, commanded and read from procedures.

Network sideEthernet to the lab networkUSB-C for service

The gateway, in a box

It carries frames. Your drivers speak protocols.

Stellar Bench runs the Stellar Control gateways, each serving one link of a target. Protocols live in the drivers and transports of Stellar Control: CSP over CAN, CCSDS frames, SCPI commands. The box needs no update when the protocol of your equipment changes.

  • Down to the equipment : frames go out exactly as the driver of the target encoded them.
  • Up to mission control : frames come back with their reception time.
  • Visible : each link reports its availability, its throughput and its health.
  • Plug in : at start-up the box registers its gateways; the system binds them to your targets from the topology, and says why a target is not ready.
  • Interchangeable : swap one box for another without touching a procedure.
One bench, several targets

Each bus is its own link

One Stellar Bench serves several targets at once. Each bus is a link of the topology, commanded and monitored on its own.

  • CANflatsat-1 · directThe thrusters' control units, reached by the tcu-can driver.
  • RS-422payload-em · dataThe payload's command and data link.
  • ETHpsu-lab-2 · scpiThe bench power supply that feeds the flatsat.
  • GPIOflatsat-1 · discretesThe line that simulates separation, set by the procedure at the right step.
Stellar Control in a data centre or the cloud, connected to benches in an integration hall, at a partner site and at the launch site Stellar Control data centre or cloud Integration hall bench-1 · bench-2 Partner site subsystem bench Launch site final checks
Anywhere, securely

The bench does not need to be next door

Keep Stellar Control in your data centre or in the cloud, and put the box in the integration hall, at a partner's site or at the launch site.

  • Encrypted : the box connects over mutual TLS, with its own certificate.
  • Least privilege : short-lived credentials, limited to the links it serves.
  • No silent loss : telecommands and telemetry go through a persistent backbone.
  • A fleet, not a pile of adapters : every box has its identity, its software version, its health and its metrics.
# The bench, described in the topology
flatsat-1:
  links:
    direct: {driver: tcu-can@2, gateway: bench-1-can}

# A step of a procedure, sent on its CAN bus
step "TCU answers"
  send ping to sat.tcu[tcu] via direct
  expect sat.tcu[tcu].responding is true within 5 s
With Stellar Control

Your hardware in the loop, your procedures unchanged

  • Simulation, then hardware : a procedure written against the simulated target runs unchanged once Stellar Bench puts the engineering model in the loop.
  • Procedures reach every bus : a telecommand goes out on the bench's CAN bus and its answer is checked within its time window.
  • Evidence : every frame archived as received, with its reception time and the version of the driver that decoded it.
  • Configuration as code : the bench is described in the topology, versioned in Git with the rest of your mission.
  • Same procedures to orbit : validated on the bench in AIT, unchanged through a ground station in flight.
Where it stands

Start with the gateways, the box follows

The gateways of Stellar Bench are Stellar Control gateways: the CAN and Ethernet ones run today on a Linux machine of your bench, with a standard CAN adapter. The interface unit brings them together in one managed box.

ImplementedRoadmap

Gateways

  • CAN Implemented

    The bench CAN gateway of Stellar Control, on SocketCAN: CSP over CAN to a flatsat, tested on the bus.

  • Ethernet and SCPI Implemented

    Lines to and from laboratory instruments over TCP, with their reachability.

  • RS-422 and RS-485 Roadmap

    Serial links with their rate, parity, termination and direction control.

  • Discrete I/O Roadmap

    Separation, enables and status lines, set and read by procedures.

  • SpaceWire Roadmap

    High-rate links to instruments and on-board computers.

The unit

  • Interface unit Roadmap

    One box with every interface, the gateways preinstalled and managed as a fleet.

Hardware

A unit for the bench

Equipment interfaces CAN, RS-422, RS-485, Ethernet, SpaceWire, discrete I/O
Network interfaces Ethernet, USB-C for service
Software Stellar Control gateways running natively, secure connection to Stellar Control, updates from get.stellar-systems.eu
Status In design: early access for integration teams
Get started

Tell us your buses. Run your first procedure.

Stellar Systems helps you from the wiring of your bench to the first procedure on your hardware.

  1. List the buses and signals of your equipment.
  2. Describe your bench in the topology.
  3. Connect the box to your equipment and to the network.
  4. Run your first procedure on your hardware.